GRAS 40BI 1/4" Ext. Polarized Intensity Microphone Kit

Freq response: IEC 61043
Dyn range: 35 dB(A) to 172 dB
Sensitivity: 4 mV/Pa

Technology

Introduction

The 40BI is an IEC 61043-compliant ¼" externally polarized sound-intensity microphone pair.

The 40BI microphone pair consists of two phase-matched free-field condenser microphones with extremely well-controlled phase characteristics for use in sound-intensity probes. Their standard mounting threads make them compatible with all the usual available makes of measurement-microphone preamplifiers.

The 40BI can be used in the GRAS 50AI Sound-Intensity Probe for high frequency sound-intensity measurements. The 50AI is delivered with ½" microphones, and the 40BI can be ordered as accessories so that you can cover a large frequency range for your sound-intensity measurements. Because the 40BI measures higher frequencies, smaller spacers - 6 mm, 12 mm, and 25 mm – are included with the 40BI kit.

40BI is individually factory-calibrated and delivered with a calibration chart stating its specific open-circuit sensitivity and pressure frequency response.

Typical applications and use

The 40BI is designed for sound-intensity and sound-power measurements, as well as sound-source localization. Each 40BI microphone pair is phase matched according to the phase specifications for a Class 1 Sound Intensity Probe in accordance with international IEC 61043, Electroacoustics - Instruments for the Measurement of Sound Intensity - Measurements with Pairs of Pressure Sensing Microphones, 1993.

The quality of a sound intensity probe microphone is its ability to measure the real part of a complex sound intensity in highly reactive sound fields as well as in sound fields exposed to high levels of background noise. This ability depends largely on the phase responses of the microphone pair. The individual phase matching of each 40BI ensures that any differences in phase responses are extremely small.

The 40BI is also used for ranking of sound sources. When mounted in a sound-intensity probe such as the 50AI, the microphones can pinpoint the area generating the most noise, which may then require additional measurements, depending on the measurement procedures and processes used. The sound-intensity microphones reveal the weak and strong points when identifying noise sources. Sound-source ranking is useful as long as the background noise doesn't exceed the noise source.

Compatibility

The 40BI requires a standardized ¼" LEMO preamplifier and an input module that supports this technology. We recommend GRAS 26AA preamplifier.

System verification

For daily verification and check of your measurement setup, we recommend using a calibrator like GRAS 42AG Multifunction Sound Calibrator.

For proper sensitivity calibration, we recommend using a pistonphone like GRAS 42AP Intelligent Pistonphone.

Calibration

When leaving the factory, all GRAS microphones have been calibrated in a controlled laboratory environment using traceable calibration equipment. Depending on the use, measurement environment and internal quality control programs we recommend that the microphone is recalibrated at least once a year.

We offer two kinds of calibration as an optional after-sales service: GRAS Traceable Calibration and GRAS Accredited Calibration.

GRAS Traceable Calibration is a traceable calibration performed by trained personnel under controlled conditions according to established procedures and standards. This is identical to the rigorous calibration that all GRAS microphones are subjected to as an integral part of our quality assurance.

GRAS Accredited Calibration is performed by the GRAS Accredited Calibration Laboratory that has been accredited in accordance with ISO 17025 by DANAK, the Danish Accreditation Fund.

If you want a new microphone set delivered with an accredited calibration in stead of the default factory calibration, specify this when ordering.

Learn more at gras/calib.

Quality and warranty

All GRAS microphones are made of high-quality materials that will ensure life-long stability and robustness. The microphones are all assembled in verified clean-room environments by skilled and dedicated operators with many years of expertise in this field.

The microphone diaphragm, body, and improved protection grid are made of high-grade stainless steel, which makes the microphone resistant to physical damage, as well as corrosion caused by aggressive air or gasses.

This, combined with the reinforced gold-plated microphone terminal which guarantees a highly reliable connection, enables GRAS to offer 5 years warranty against defective materials and workmanship.

Service

If you accidentally damage the diaphragm on a GRAS microphone, we can — in most cases — replace it at a very reasonable cost and with a short turn-around time. This not only protects your investment, but also pleases your quality assurance department because you don’t have to worry about new serial numbers, etc.

Specifications

Polarization/Connection
0 V / CCP
Frequency range (±1 dB)
Hz
IEC 61043 Class 2
Dynamic range lower limit (microphone thermal noise)
dB(A)
30
Dynamic range lower limit with GRAS preamplifier
dB(A)
35
Dynamic range upper limit
dB
172
Dynamic range upper limit with GRAS preamplifier @ +28 V / ±14 V power supply
dB
163
Dynamic range upper limit with GRAS preamplifier @ +120 V / ±60 V power supply
dB
172
Polarization voltage
V
200 V / Traditional
Microphone venting
Rear
IEC 61094-4 Compliance
WS3P
Temperature range, operation
°C / °F
-40 to 150 / -40 to 302
Temperature range, storage
°C / °F
-40 to 85 / -40 to 185
Temperature coefficient @250 Hz
dB/°C / dB/°F
-0.01 / -0.006
Static pressure coefficient @250 Hz
dB/kPa
-0.008
Humidity range non condensing
% RH
0 to 100
Humidity coefficient @250 Hz
dB/% RH
-0.001
Influence of axial vibration @1 m/s²
dB re 20 µPa
59
CE/RoHS compliant/WEEE registered
Yes / Yes, Yes
Weight
g / oz
1.5 / 0.053

Difference in phase response
From 20 Hz to 1000 Hz < 0.2°
From 1000 Hz to 10 kHz < f [kHz] x 0.2°

Difference in amplitude response (normalised at 250 Hz)
From 20 Hz to 2 kHz < 0.2 dB
From 2 Hz to 10 kHz < 0.3 dB

Difference in sensitivity at 250 Hz < 2dB

GRAS Sound & Vibration reserves the right to change specifications and accessories without notice.

 

 

Ordering info

Optional items

GRAS 26AA Set

1/4" Preamplifier with Integrated Cable for Intensity Probes

GRAS 42AG

Multifunction Sound Calibrator

GRAS 42AP

Intelligent Pistonphone, Class 0

GRAS CA0001

Traceable Calibration of Microphone

GRAS CA2001

Accredited Calibration of Microphone

GRAS Sound & Vibration reserves the right to change specifications and accessories without notice.